Turbo PMAC2 Realtime Express Controller
Software Setup
I100 Motor 1 Activation Control should always be equal to 1. Meaning at least 1
drive/motor should be connected to the controller. This setting is done in the
PANADWLD.PMC file.
Ixx01 Motor xx Commutation Enable
This should be 0 for all the motors except motor #1 for which the default value is 1 and
should not be changed.
I101 Motor 1 Commutation Enable should always be 1
Ixx03 Motor xx Position Loop Feedback Address
Ixx04 Motor xx Velocity Loop Feedback Address
Ixx08 Motor xx Position Scale Factor
Should be set to 8
Ixx09 Motor xx Velocity-Loop Scale Factor
Should be set to 8
Ixx10 Motor xx Power-On Servo Position Address
If you have absolute feedback and the value is being sent over the RX buffer in the same memory
location of Actual position, you can set up the power-on position address Ixx10 based on the
following values: