Turbo PMAC2 Realtime Express Controller
Software Setup
37
Motor Motion I-Variables
Ixx24 Motor xx Flag Mode Control (Is a PMAC 1 Type)
Since the amp-fault is a low true on the Panasonic drives, you need to have bit 23 set to 1.
($800000)
Ixx25 Motor xx Flag Address
I-Variable
Value
I-Variable
Value
I-Variable
Value
I-Variable
Value
I125
$A4
I925
$4A4
I1725
$8A4
I2525
$CA4
I225
$124
I1025
$524
I1825
$924
I2625
$D24
I352
$1A4
I1125
$5A4
I1925
$9A4
I2725
$DA4
I425
$224
I1225
$624
I2025
$A24
I2825
$E24
I525
$2A4
I1325
$6A4
I2125
$AA4
I2925
$EA4
I625
$324
I1425
$724
I2225
$B24
I3025
$F24
I725
$3A4
I1525
$7A4
I2325
$BA4
I3125
$FA4
I825
$424
I1625
$824
I2425
$C24
I3225
$1024
Motor xx PID Servo Setup I-Variables
Ixx30 Motor xx PID Proportional Gain
(USED FOR A DIFFERENT PURPOSE WITH PANASONIC)
Panasonic TX Block Number
Ixx30 is the Panasonic TX Block number for the xx Motor. Needs completion for number
of Panasonic motors.
Ixx31 Motor xx PID Derivative Gain
(USED FOR A DIFFERENT PURPOSE WITH PANASONIC)
Panasonic Mac ID Number
Ixx31 is the Panasonic Mac ID number for the xx Motor. Needs completion for number
of Panasonic motors.
NOTE
Ixx30 and Ixx31 must match the order block number and Mac
ID of the Ring even though the node might be an I/O node.
Slave I/O nodes should be put in the Ixx30 & 31 variables after
the Servo nodes. There can be no GAPS in the Ixx30/31
variables. For example, you cannot use Motor 5's I530/531
variables if you only have 4 Nodes.
Important:
Current Panasonic setup code only supports 1 block slave nodes.