The Macro Connector will be used to form a
ring between all the MACRO components of
the system.
For RJ-45 connector, standard CAT-5 or CAT-
6 cables with standard RJ-45 connection can
be used to form the ring.
For FIBER option, fiber cable with SC-style
connectors is used as communication medium
between the MACRO stations
Ethernet connection can be used either for
communication between the unit and a PC as
user interface or with MODBUS option it can
be configured as MODBUS MASTER or
SLAVE for expanding the control solution.
USB connection can be used either for
communication between the unit and a PC as
user interface.
FIELDBUS connector gets connected directly
to the Hilscher module inside the unit and the
SyCon software for setting up the module
The FIELDBUS connector is the main
connector between the Hilscher module and
the optional FieldBus network. Please check
the pin out configuration section carefully.
Serial Connection (RS-
232) can be used to talk to
the CPU directly. Since the
parser on this port can be
turned off, it can also be
used for communicating to
the 3
rd
party devices over
RS-232
By holding FW LOAD micro-switch while
power-up, you can place the card in
Bootstrap mode for loading firmware
By holding RE-INIT micro-switch while power-
up, the card will load the factory default
settings instead of saved settings on FLASH
24VDC
0.75 A continues
1.8 A start up