Turbo PMAC2 Realtime Express Controller
Software Setup
RESERVED M & P VARIABLE FOR PANASONIC IMPLEMENTATION
M8100 - M8191
P8191
Since these variables have been used in user-written servo, phase and PLCC1, writing into these
variables or changing their definition can cause unexpected behavior in the system.
UNAVAILABLE PMAC COMMANDS FOR PANASONIC IMPLEMENTATION
Certain PMAC commands are not available on the Realtime Express Controller. These
commands can stop the controller by stopping the network from:
HMZ
HM1..32 (home search command from any motion program)
$$$ (To reset power cycle, or command M8123 = 8 in terminal window)
$$$*** but then must reload Panasonic, SAVE and power cycle
$ (To recover set M8123 = 5)
Ctrl-D (To recover, power cycle)
Any move until trigger
Programming DISPLAY commands
RESERVED PMAC I-VARIABLES FOR PANASONIC IMPLEMENTATION
General Global Setup I-Variables
These I-variables should not be changed. They are specifically set for Realtime Express Network.
I5 PLC Program Control
Default: 3
Range: 1 or 3
I7 Phase Cycle Extension
Default: 0
I10 Servo Interrupt Time (Set for Panasonic rate)
Default: 8388607
Motor Setup I-Variables
Ixx00 Motor Activation Control
Must be set to 1 for each active motor.