Delta Tau GEO MACRO DRIVE User Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 205
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
Geo MACRO Drive User and Reference Manual
Connections 35
Hiperface® Interface
The Geo Drive will read the absolute data from the Hiperface® interface only if the appropriate option is
ordered. (Not yet released firmware).
Hardware Setup
The differential format provides a means of using
twisted pair wiring that allows for better noise
immunity when wired into machinery.
Safe data transmission
Absolute positioning
Only 8 leads
The wiring diagram to the right shows an example
of how to connect the Geo Drive with Hiperface.
Function Pin#
Sin+/ ChA+ 1
Cos+/ChB+ 2
Sin-/ChA- 14
Cos-/ChB- 15
DATA+ 7
DATA- 20
ENCPWR/5V 12/24
GND 13/25
Note: We assume the Hiperface Interface power
requirements are for 5V, else use of an external
power supply for the Hiperface is required. Tie
together the Geo Drive GND and the power supply
GND for noise immunity.
2
3
4
5
14
15
16
17
1
6
7
18
19
8
9
20
21
10
11
22
23
12
13
24
25
Hiperface® Interface
X1/X2
Sin+
Cos-
Sin-
Cos+
+5V
GND
Shield
In_Therm_Mot
DATA
DATA
1Vpp A
1Vpp B
Hiperface Interface
Up Power
0V Supply
DATA+
DATA-.
Page view 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 204 205

Comments to this Manuals

No comments