Geo MACRO Drive User and Reference Manual
Specifications 13
Environmental Specifications
Description Unit Specifications
Operating Temperature °C +0 to 45°C. Above 45°C, derate the continuous peak output current by
2.5% per °C above 45°C. Maximum Ambient is 55°C
Rated Storage Temperature °C -25 to +70
Humidity % 10% to 90% non-condensing
Shock Call Factory
Vibration Call Factory
Operating Altitude Feet
(Meters)
To 3300 feet (1000meters). Derate the continuous and peak output
current by 1.1% for each 330 feet (100meters) above the 3300feet
Air Flow Clearances in (mm) 3" (76.2mm) above and below unit for air flow
Recommended Fusing and Wire Gauge
Model Recommended Fuse (FRN/LPN) Recommended Wire Gauge*
GxL012xx 15 14 AWG
GxL032xx 20 12 AWG
GxL051xx 20 12 AWG
GxL052xx 20 12 AWG
GxL101xx 20 12 AWG
GxL102xx 20 12 AWG
GxL151xx 25 10 AWG
GxL152xx 25 10 AWG
GxL201xx 25 10 AWG
GxL301xx 30 8 AWG
GxH012xx 15 14 AWG
GxH032xx 20 12 AWG
GxH051xx 20 12 AWG
GxH052xx 20 12 AWG
GxH101xx 20 12 AWG
GxH102xx 20 12 AWG
GxH151xx 25 10 AWG
GxH152xx 25 10 AWG
GxH201xx 25 10 AWG
GxH301xx 30 8 AWG
* See local and national code requirements
Wire Sizes
Geo Drive electronics create a DC bus by rectifying the incoming AC electricity. The current flow into
the drive is not sinusoidal but rather a series of narrow, high-peak pulses. Keep the incoming impedance
small so that these current pulses are not hindered. Conductor size, transformer size, and fuse size
recommendations may seem larger than normally expected. All ground conductors should be 8AWG
minimum using wires constructed of many strands of small gauge wire. This provides the lowest
impedance to high-frequency noises.