Geo MACRO Drive User Manual
186 Appendix D
APPENDIX D
MACRO Flag Transfer Location
For proper servo operations, the Master Controller must process information in real time. For MACRO
systems, this information is brought to the Master via Ixx25. For Turbo systems, the locations are at
$3440, $3441, $3444, $3445, $3448, $3449, $344C, $344D, etc. The following tables list the data that is
transferred through these locations.
NodeCntrlStatus: (Sent by Slave - Located in gate array except for bits 0-7)
(Turbo at: X:$3440 .. X:$347F / X-portion of Flag Address)
Bit Function
0 Not Used
1 Not Used
2 Not Used
3 Not Used
4 Not Used
5 Not Used
6 Not Used
7 Not Used
8 Encoder Count Error
9 Position compare (EQUn) output
10 Position captured-on-gated -index flag.
11
* Position Captured (Triggered Event Occurred) Flag.
12
A Power On Reset POR has occurred.
13
This Node detected a MACRO Ring Break (MRB).
14
Amplifier Enabled.
15
* Amplifier or Station Node shutdown Fault.
16 Home Flag(HMFLn) Input Value
17
* Positive End Limit Flag (PILMn) Input Value.
18
* Negative End Limit Flag (NILMn) Input Value
19 Fast User Status Flag (UserStatus1) or USERn Input Value if have PMAC Gate Array
20 Fast User Status Flag (UserStatus2) or FlgWn Input Value if have PMAC Gate Array
21 Fast User Status Flag (UserStatus3) or FlgVn Input Value if have PMAC Gate Array
22 Fast User Status Flag (UserStatus4) or FlagUn Input Value if have PMAC Gate Array
23 Fast User Status Flag (UserStatus5) or FlagTn Input Value if have PMAC Gate Array
Note: The items in bold are reserved and defined flag locations.