Delta Tau PMAC2 PCI User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
PMAC2 User Manual
10 Basic Motor Setup on PMAC2
ADC Input
Value A
ADC Input
Value B
ADC Frequency
Control
ADC Strobe
Control
24
Data
6
Address
ADC Shift
Register A
ADC Shift
Register B
ADCINA
ADCINB
ADCCLK
ADCSTROBE
PHASE
CLOCK
Indicates that one register controls
all ADC input channels on IC
*
*
*
Figure 6 PMAC2 Gate Array IC Input Channel
Parameters to Set up Motor Operation
Each Motor x has setup I-variables to permit specific software configuration of that motor’s control
algorithms. The hundred’s digit of the I-variable specifies which motor is being configured; for example
I100 activates or de-activates Motor 1. The generic reference for the variable uses the letter x for the
motor digit; Ix00 refers generally to the activation variable for Motor x, where x = 1 to 8.
Most of the software configuration of a motor involves setting proper values for these variables, as
explained in the following sections. This section has a quick survey of the key variables, and the
variables that are common to all modes.
Activating the Motor
The Ix00 motor activation parameter must be set to 1 for any motor that is to be used on PMAC2. It
should be set to 0 for any motor that is not used, so PMAC2 will not waste computation time on that
motor.
Does PMAC Commutate the Motor?
The Ix01 commutation enable parameter must be set to 1 if PMAC2 is performing the commutation
and/or digital current loop for the motor. It must be set to 0 for any motor if PMAC2 is performing
neither the commutation nor digital current loop for the motor.
Command Output Address
Ix02 specifies the addresses of the registers to which PMAC2 writes the command outputs for the motor.
The default values of Ix02 contain the address of the A command register in DSPGATE1. For the
machine interface channel n, where n = x; these values are suitable for analog output modes with and
without commutation, and for direct PWM control.